ProfiTrace 2 - Mobile PROFIBUS Combi-Analyzer

profitrace2-promo-200ProfiTrace 2 is the most powerful mobile analyzer for PROFIBUS networks. It is the latest generation in the line of busmonitor technology. Thousands of users benefit daily from this great tool. ProfiTrace combines all required tools in one:
 Red-Square-BulletBusmonitor
 Red-Square-BulletOscilloscope
 Red-Square-BulletBar graph
 Red-Square-BulletTopology Scan
 Red-Square-BulletReporting
 Red-Square-BulletDP Master


Technicians can check and troubleshoot the complete PROFIBUS network with 1 software package and 1 piece of hardware. This is an enormous reduction in equipment, weight, costs and required knowledge. The advanced USB hardware (ProfiCore™ Ultra) is internally equipped with a high-speed digital oscilloscope and able to capture bus signals running at 12 Mbps.

ProfiTrace is an essential tool for maintenance, commissioning and troubleshooting as well as product development. Typical failures such as noise, reflections, voltage drops, termination problems, double addresses, wire breaks and configuration faults are easily identified. Random errors such as overshoots, error telegrams, repeats and diagnostics can also be captured and logged. The results can be exported to detailed reports which are accepted by the industry. Predictive maintenance and asset management are really possible with ProfiTrace! This outstanding tool that fits in your pocket, will boost the capabilities of service, maintenance and engineering technicians.
Product features

green-tick Busmonitor for DP and PA with powerful statistics
Repeats, fall-outs, corrupted messages, diagnostics, cycle time, etc.
green-tick High-speed digital oscilloscope - ScopeWare
Differential voltage, A-line, B-line, noise, overshoots, reflections, triggers.
green-tick Bar graph
Average, Min. and Max. values of the bus signals per device.
green-tick Topology Scan
Automatic generation of the network topology.
green-tick Reporting
Automatic generation of detailed reports that are accepted by the industry.
green-tick DP master - ProfiCaptain
A complete DP master has been integrated (V0 and V1).
green-tick ProfiCore Ultra USB interface
Useable on PC platforms, no power supply required and elimination of spur lines.
green-tick OPC server and CommDTM
green-tick XP, Vista and Windows 7 platforms
green-tick Multi language user interface
Application areas

green-tick Troubleshooting & maintenance of PROFIBUS networks
(ProfiTrace, ScopeWare, Topology scan and ProfiCaptain)
green-tick Commissioning of PROFIBUS networks
(ProfiTrace, ScopeWare, Topology scan and ProfiCaptain)
green-tick PROFIBUS product testing and verification
(ProfiTrace, ScopeWare, ProfiCaptain and CommDTM)
green-tick Passive cable testing
(ScopeWare and ProfiCaptain)
green-tick I/O testing of PROFIBUS devices
(ProfiCaptain)
green-tick Setting up and diagnose PROFIBUS devices
(CommDTM)
green-tick Address setting of PROFIBUS devices
(ProfiCaptain)
green-tick Interface for bus statistics and device I/O to external apps
(OPC server)
green-tick Education
Live List

profitrace2-livelist-180 blank "Colours make it easy….."

The Live List is a matrix that continuously lists all the available devices. It is directly visible which devices are ‘troublemakers’.
With different background colours the status of the devices is displayed;
- Green: Device is in Data Exchange
- Yellow: Device is lost
- Red: Parameter fault
- Purple: Configuration fault
- No colour: Not in Data Exchange
The Live List can also generate the product name of the devices when a diagnostic message is captured (synchronized with the GSD library).
Statistics matrix

"Click and go….."

The statistics matrix is the most powerful feature of the analyzer. This field can really indicate what the condition of the installation is. It displays all the important information that a user, especially a maintenance technician is really interested in;
 Red-Square-BulletRetry messages
 Red-Square-BulletFall-outs
 Red-Square-BulletBus cycle time
 Red-Square-BulletDiagnostic messages, etc.

Because of this feature, the user does not have to inspect messages or do difficult operations to ensure the quality of the installation.

If the statistics do NOT show deviations, the installation is on the 1st degree OK!!!
Message recording

"The absolute truth....."

When the user records messages, he has a perfect visual representation on the screen;

 Red-Square-BulletVisualization of FDL, DP, DP-V1, DP-V2, PA and I&M messages.
 Red-Square-BulletMessages can be filtered and stored.
 Red-Square-BulletData interpretation of bytes, words, floating points, etc.
 Red-Square-BulletError detection.
 Red-Square-BulletBookmarks.
profitrace2-repeats-180
ScopeWare (DP)

profitrace2-scopeware1-180 "The easiest oscilloscope ever....."

With the built in oscilloscope we can detect; noise, reflections, termination problems, etc.

 Red-Square-BulletTime scale: 50 ns to 500 ms.
 Red-Square-BulletVoltage scale: 0,5 to 5 V per DIV.
 Red-Square-BulletCursors (voltage and time).
 Red-Square-BulletDifferential (B-A) and single ended (A and/or B line) measurements.
 Red-Square-BulletTrigger per device or free running.
 Red-Square-BulletTrigger features: start of response, request message and voltage level.
 Red-Square-BulletBit interpretation engine.
ScopeWare (PA)

0048  Red-Square-BulletAll features of ScopeWare DP.
 Red-Square-BulletMax. 33 V DC.
 Red-Square-BulletMax. 1,2 Vtt AC.
 Red-Square-BulletAC and DC can be displayed simultaneously.
 Red-Square-BulletDetects missing termination.
 Red-Square-BulletPA Probe Ultra is required.
Bar graph

profitrace2-bargraph1-180 The bar graph is a helpful utility to get an impression of the overall signal quality of the network.

 Red-Square-Bullet2 Selectable modes: Average signal level and minimum difference between 1 and 0.
 Red-Square-BulletAverage, min. and max. signal level indicator.
 Red-Square-BulletColours state the quality of the signals.
 Red-Square-BulletCan be sorted on: address and Voltage.
 Red-Square-BulletContinuously updated.
Topology scan

 Red-Square-BulletAutomatic generation of the network topology.
 Red-Square-BulletNo shutdown required!
 Red-Square-BulletNo disturbance in the cycle time!
 Red-Square-BulletWorks on 500 kbps and 1,5 Mbps.
 Red-Square-BulletOn passive networks in conjunction with ProfiCaptain.
ProfiTrace2-topology-180
Reporting

"We have proof….."

The reporting feature creates a detailed report that contains the signals of all devices, their faults, the network topology, bar graph and administrative information.

 Red-Square-BulletGeneration of detailed network reports.
 Red-Square-BulletAddress list with manufacturer information.
 Red-Square-BulletOscilloscope images of every device.
 Red-Square-BulletLive List, Bar graph and Topology structure.
 Red-Square-BulletSummary of detected errors.
 Red-Square-BulletStandard layout for signatures and approvals.
 Red-Square-BulletImport of company logo.
profitrace2-reporting-180
ProfiCaptain - DP Master

"Test and control your devices....."

 Red-Square-BulletComplete integration of ProfiCaptain.
 Red-Square-BulletPutting slaves in Data Exchange.
 Red-Square-BulletI/O control with automatic patterns.
 Red-Square-BulletAutomatic detection of existing busparameters.
 Red-Square-BulletBrand new concept of 'stealing' slaves.
 Red-Square-BulletClass 2 functions in a Class 1 framework.
 Red-Square-BulletNo shutdowns when updating the configuration.
 Red-Square-BulletDeactivating slaves in the configuration.
profitrace2-proficaptain-180
ProfiCore™ Ultra

ProfiCore-Ultra-200PROFIBUS
 Red-Square-Bullet12 Mbps (all baudrates)
 Red-Square-BulletGalvanic isolated PROFIBUS interface
 Red-Square-BulletLatest RS 485 technology

Oscilloscope
 Red-Square-BulletFrequency: 2 x 192 MHz
 Red-Square-BulletBandwidth: 100 MHz
 Red-Square-BulletDifferential measurement: -9..+9 V
 Red-Square-BulletSingle ended: -4,5..+8 V

Others
 Red-Square-BulletHigh-speed USB 2.0 interface
 Red-Square-BulletExternal power supply possible if required

ProductsPriceOrder codeDescription
0033
Troubleshooting
Toolkit Ultra Plus
Contact us 37021 • ProfiCore Ultra
• USB cable
• ProfiTrace 2

• ScopeWare
• Bar graph
• Topology Scan
• Reporting
• Tap Connector
• Blue carrying case
0033
Troubleshooting
Toolkit Ultra Pro
Contact us 38022 • ProfiCore Ultra
• USB cable
• ProfiTrace 2

• ScopeWare
• Bar graph
• Topology Scan
• Reporting
• Tap Connector
• Blue carrying case

• OPC Server
• PA Probe Ultra
• ProfiCaptain

 

Click here to see accessories and more add-ons